EKey Fingerscan Access Control System Installationshandbuch Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 64
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
(941) 782-1227
info@ekeyUSA.com
ekeyUSA Catalog
2013
ekeyusa_catalog_2012_v7
5.1.2 ekey net Access ScannerInstallation Specification
DETAILS
WALL MOUNT SCANNER
INTEGRA ENHANCED
SCANNER
INSTALLATION SPECIFICATION
Supply Voltage
8-24VAC or 8-24V D C
Current draw Idle mode
(12VDC)
85mA
Current d r a w M a t c h i n g
mode (12VDC)
90mA
Power Consumption
(idle & matching)
~1W
Dimensions (WxHxD):
1
3/4
x 3
3/16
x 2
3/8
in
(45x81.55x60.2mm)
Housing 1
3/4
x 3
1/2
x
¾
in
(43.6 x 89 x 17.3 mm)
Storage & Operating Temp.
-4° F to -167° F
(-20° C up to 75° C)
-13° F to -158° F
(-25° C up to 70° C)
Humidity
Max. 95% relative, non condensing
Max. 95% relative, non
condensing
Protection Class
IP44
International Protection
(IP54)
Installation Height
at least 53 inches (135 cm) from
scanner lower edge
At least 62 inches (155 cm)
from scanner lower edge
Mounting Type
Surface mount
Flush mount
Control Cable Tip
4-pole push terminal RM 3.5
R J 4 5 S h o r t b o d y - only 4 pins are
used
(Cable supplied b y e k e y type
A;)
Pin Assignment
Pin 1&2 data;
Pin 3&4 power
Pin 4&5 data; Pin 7&8 power;
Pin 1,2,3, & 6 not used
Control Cable Wiring
CAT5 up to 300ft; 16AWG for longer runs; Max cable length 1000ft
Seitenansicht 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 63 64

Kommentare zu diesen Handbüchern

Keine Kommentare